Q Bank & Answer - Electrical Engineer - EMU & MEMU

1.Rating of EMU transformer is

(a) 1200KVA 

(b) 1000KVA 

(c) 800 KVA

(d) 1100KVA 

Answer - (b) 1000KVA 


2.Voltage rating of EMU Traction Motor is

(a) 500 V 

(b) 580 V 

(c) 535 V 

(d) 550 V 

Answer - (c) 535 V 

3.New wheel diameter of EMU Motor Coach/Trailer coach

(a) 900 mm 

(b) 950 mm 

(c) 850 mm 

(d) 952 mm 

Answer -  (d) 952 mm 


4.Total auxiliary motors in EMU motor coach are

(a) 5 

(b) 4 

(c) 3 

(d) 2 

Answer - (a) 5 


5. Total No. of traction motors in a EMU Motor Coach is

(a) 2 

(b) 3 

(c) 4 

(d) 5 

Answer - (c) 4 


6. The Safety device provided in EMU for detecting gassing and the protection of Transformer is:

(a) OLP 

(b) TTR 

(c) BUD 

(d) PRV 

Answer - (b) TTR 


7. The Safety device fitted in the EMU Transformer for its protection against explosion:

(a) PRV 

(b) OLP 

(c) BUD 

(d) TTR 

Answer - (a) PRV 


8. The Ampere hour capacity of EMU battery is :

(a) 80 Ah 

(b) 90 Ah 

(c) 100 Ah 

(d) 75 Ah 

Answer - (b) 90 Ah 


9. The type of Traction Motor used in EMU is :

(a) 4001 BX 

(b) 4601 BX 

(c) 6040 BX 

(d) None of the above

Answer - (b) 4601 BX 


10. The No of teeth in EMU traction motor pinion is :

(a) 19 

(b) 20 

(c) 55 

(d) 91 

Answer - (b) 20 


11. The gear ratio in EMU is ;

(a) 1 : 4 

(b) 1 : 5 

(c) 1 : 4.55 

(d) 1 : 5.55 

Answer - (c) 1 : 4.55 


12.The control voltage in EMU is ;

(a) 110 V AC 

(b) 230 V AC 

(c) 110 V DC 

(d) 230 V DC

Answer - (c) 110 V DC 


13. The rating of EMU traction motor is :

(a) 150 KW 

(b) 535 KW 

(c) 230 KW 

(d) 167 KW

Answer - (d) 167 KW


14. The type of cooling of transformer oil is :

(a) OFAF 

(b) OF 

(c) AF 

(d) None of the above

Answer - (a) OFAF 


15. The voltage of primary winding of EMU transformer is :

(a) 25 KV 

(b) 266 V 

(c) 782 V 

(d) None of the above

Answer - (a) 25 KV 


16. The voltage of Secondary winding of EMU transformer is :

(a) 25 KV 

(b) 266 V 

(c) 782 V 

(d) None of the above

Answer -  (a) 25 KV 


17.The voltage of Auxiliary I winding of EMU transformer is :

(a) 25 KV 

(b) 266 V 

(c) 782 V 

(d) None of the above

Answer - (a) 25 KV 


18. The voltage of Auxiliary II winding of EMU transformer is :

(a) 141 V 

(b) 266 V 

(c) 782 V 

(d) None of the above

Answer - (a) 141 V 


19. The No of main poles in EMU traction motor is :

(a) 2 

(b) 4 

(c) 6 

(d) None of the above

Answer - (a) 2 


20. The BDV stands for :

(a) Break down value 

(b) Break down voltage 

(c) Break drop voltage

(d) None of the above

Answer - (b) Break down voltage 


21. The BDV for new filtered oil for transformer is :

(a) 40 KV 

(b) 60 KV 

(c) 30 KV 

(d) None of the above

Answer - (a) 40 KV 


22. The capacity of main compressor in EMU is:

(a) 900 lpm 

(b) 1000 lpm 

(c) 500 lpm 

(d) None of  the above

Answer - (b) 1000 lpm 


23. The rating of MCP in EMU is:

(a) 12 HP 

(b) 10 HP 

(c) 20 HP 

(d) None of the above

Answer -  (a) 12 HP 


24. The No of carbon brushes in TM are :

(a) 2 

(b) 4 

(c) 6 

(d) 8

Answer - (d) 8


25. The condemning size of TM carbon brush is :

(a) 32 mm 

(b) 40 mm 

(c) 35 mm 

(d) None of the above

Answer - (a) 32 mm 


26. The type of TM suspension in EMU is ;

(a) Fixed 

(b) Axle hung nose suspended

(c) Mounting pad

(d) None of the above

Answer - (b) Axle hung nose suspended


27. The function of Aux rectifier is to feed :

(a) Aux I circuit 

(b) Battery charger 

(c)Main Compressor

(d) None of the above

Answer - (c)Main Compressor


28. The function of DC-DC converter is to feed :

(a) Flasher light 

(b) Head light 

(c) Tail lamp 

(d) None of the above

Answer - (b) Head light 


29. The number of batteries available in EMU are :

(a) 5 

(b) 8 

(c) 10 

(d) None of the above

Answer - (c) 10 


30.If Traction motor No 4 is grounded, which of the following relay will act?

a) OL 1&2 

(b) OL 3&4 

(c) EFRP 

(d) EFRA-II 

Answer - (c) EFRP 


31. Fans in EMU are working with

a) 110 V AC 

(b) 110 V DC 

(c) 141 V AC 

(d) 266 V AC

Answer -  (d) 266 V AC


32. Battery used in EMU is

a) Ni-Cd Cell 

(b) Lead acid cell 

(c) Dry cell 

(d) Edison cell

Answer - (b) Lead acid cell 


33. Number of interpoles used in TM 4601 BX is

a) 4 

b) 2 

c) 6 

d) 8 

Answer - a) 4 


34. HRC fuses for protecting the battery is rated at

a) 100 A 

b) 120A 

c) 70 A 

d) 80A 

Answer - d) 80A 


35. HRC fuse rating of static battery charger

a) 16 A 

b) 5 A 

c) 32 A 

d) 10 A 

Answer - c) 32 A 


36. MCB rating for radiator fan

a) 10 A 

b) 5 A 

c) 15 A 

d) 10 A 

Answer - b) 5 A 


37. MCB rating for rectifier fan

a) 10 A 

b) 5 A 

c) 15 A 

d) 10 A 

Answer - a) 10 A 


38. Oil pump has a capacity of

a) 1 H.P 

b) 1.5 HP 

c) 0.5 H.P 

d) 2 H.P 

Answer - b) 1.5 HP 


39. Rectifier fan has a capacity of

a) 1 H.P 

b) 1.5 HP 

c) 0.5 H.P 

d) 2 H.P 

Answer - a) 1 H.P 


40. Radiator fan has a capacity of

a) 1 H.P 

b) 1.5 HP 

c) 0.5 H.P 

d) 2 H.P 

Answer - c) 0.5 H.P 


41. Forward and Reverse direction of TM is controlled through which wires?

a) 1&2 

b) 1&3

 c) 3&4 

d) 5&6

Answer - d) 5&6


42. Traction Ammeter is connected to which TMs?

a) 1&2 

b) 1&3 

c) 3&4 

d) 5&6 

Answer - b) 1&3 


43. Rated Voltage of Motor Contactors is

a) 1300 V 

b) 1500 V 

c) 500 V 

d) 1000 V 

Answer - b) 1500 V 


44. Which of these relays cause motor contactors to open?

a) EFRA - II 

b) OLP 

c) PRV 

d) RFAR 

Answer - b) OLP 


45. Static battery Charger output is

a) 90 V DC 

b) 266 V AC 

c) 110 V DC 

d) 266 V DC 

Answer -  c) 110 V DC 


46. Battery Charger failure will result in the glowing of Lamp

a) MSTWL 

b) PFD 

c) VCB OFF 

d) BCFR 

Answer - c) VCB OFF 


47. Fans power circuit is protected by HRC fuse of

a) 16 A 

b) 32 A 

c) 63 A 

d) 20 A 

Answer - c) 63 A 


48. Lights Power circuit is protected by HRC fuse of

a) 16 A 

b) 32 A 

c) 63 A 

d) 20 A 

Answer - c) 63 A 


49. Type of motor used in Auxiliary compressor is

a) DC Shunt 

b) Squirrel cage 

c) Synchrounous 

d) DC series

Answer - c) Synchrounous 


50. EMU Motor coach tare weight is approx

a) 31.04 tonnes 

b) 48.31 mm 

c) 63.77 tonnes 

d) 56.52 tonnes

Answer - c) 63.77 tonnes 


51. EMU trailer coach tare weight is approx

a) 31.04 tonnes 

b) 48.31 mm 

c) 63.77 tonnes 

d) 56.52 tonnes

Answer - a) 31.04 tonnes 


52. Working voltage for head light is

a) 50 V DC 

b) 24 V DC 

c) 110 V DC 

d) 100 V DC 

Answer - b) 24 V DC 


53. Maximum OHE voltage is

a) 25 KV 

b) 27.5 KV 

c) 30 kV 

d) none of these

Answer -  b) 27.5 KV 


54.Minimum OHE voltage is

a) 25 KV 

b) 10KV 

c) 17.5 kV 

d) none of these

Answer - b) 10KV 


55. Vendor coach in EMU can be found in coach type

a) B 

b) C 

c) D 

d) none of these

Answer - b) C 


56. First Class coach in EMU can be found in coach type

a) B 

b) C 

c) D 

d) none of these

Answer -  b) C 


57. Which of the following TM is only used in EMU?

a) 4601 BX 

b) 4303 BY

 c) C1005 TM 

d) None of these

Answer - b) 4303 BY


58. In a 3 Phase EMU rake the leading coach is 

MC 

TC 

DTC 

ND

TC

Answer - DTC 


59. The motor coach in a 3 phase EMU unit is found in

a) Both end coaches 

b) Middle coach 

c) All coaches 

d) End Coach 

Answer -  c) All coaches 


60. The conversion method from single phase (25KV) to 3 phase is using

a) Rotary Converter 

b) Phase converters 

c) Digital phase converters

d) Rectifier - Inverter

Answer -   c) Digital phase converters


61. Which of the following equipments is NOT found in motor coach of a 3 phase EMU unit?

a) Line voltage transformer 

b)Auxilliary Converter 

c) Main Compressor

d) Line Filter

Answer -   c) Main Compressor


62. in a 3 phase EMU unit , TCMS stands for

a) Traction Control Management System

b) Traction cable management System

c) Train cable management System

d) Train Control Managem ent System

Answer - c) Train cable management System


63. Communication between different components in train is facilitated by

a) TCMS 

b) GDU 

c) BECU 

d) IGBT

Answer - c) BECU 


64. Rated Voltage of 3 Phase motor used is

a) 535 V 

b) 1500 V

c) 940 V 

d) 745 V 

Answer - c) 940 V 


65. Rated power of 3 phase motor used in 3 phase EMU is

a) 535 kW 

b) 150 kW 

c) 268 kW 

d) 745 kW 

Answer - c) 268 kW 


66. In 3- Phase EMU the battery box is located in

a) MC 

b) DTC 

c) TC 

d) None 

Answer - c) TC 

No comments:

Disclaimer: The Information/News/Video provided in this Platform has been collected from different sources. We Believe that “Knowledge Is Power” and our aim is to create general awareness among people and make them powerful through easily accessible Information.

NOTE: We do not take any responsibility of authencity of Information/News/Videos.

INDEX II

Q Bank - Establishment / Personnel Dept. (82) Q Bank - Electrical Engineering (79) Q Bank - OS / Clerk / Typist (71) Q B Engg (P Way & Work) (67) Q BANK - Operating (61) Group 'B' Exam (60) Q Bank - APO ( Asst. Personnel Officer) (57) QUESTION BANK WITH ANSWER (55) Q B Establishment (47) Q Bank - Goods Guards (45) Q Bank - OHE/TRD/PSI (36) Q B - CIVIL ENGINEERING (AEN) (27) Q B - Welfare Inspector (27) Q BANK - C & W ( Carriage & Wagon ) (25) Q Bank - Account (24) Q BANK - LOCO (23) Q BANK Exam - Station Master (23) Q Bank - Commercial (21) Q Bank - AOM (19) Q BANK - Station Master (18) Q Bank - S & T (14) 1. Syllabus (12) Q Bank - D & AR (Discipline and Appeals Rule) (12) Q Bank - Medical (12) Q Bank - Posts (Civil Engineering & P way) Dept (12) 2. Q Bank - Group D To C (11) INDEX (11) QB - ENGINEERING ( MECHANICAL ) (11) Q Bank - LOCO (Diesel) (9) Q Bank - ACM (Assistant Commercial Manager) (9) Q BANK - Jr Engineer ( Diesel Mechanical ) (8) Q BANK - LOCO (AC) (8) Q Bank - Law Assistant (8) Q Bank - AME/AWM (7) Q Bank - Group D To C (6) Q Bank - Stores (5) RRB EXAM (5) NTPC (4) Q Bank - ADSTE / ASTE (4) Q Bank - CLI (4) Q Bank - General Knowledge (4) Q Bank - Publicity Inspector (4) Q Bank - Rajbhasha (राजभाषा) (4) Question & Answer (4) Q Bank - AEE (3) Q Bank - Appointment On Compassionate Ground Exam (3) Q Bank - Commercial Instructor Exam (3) Q Bank - Engineering (Bridge) (3) Q Bank - IT (3) Q Bank - Protocol Inspector (3) Q Bank - RPF Department (3) Short Notes (3) Q BANK - Jr Engineer ( Mechanical ) (2) Q Bank - C & M (2) Q Bank - Carpenter (2) Q Bank - General English (2) Q Bank - Jr Engineer (Tele) (2) Q Bank - Ministerial Staff (2) Q Bank -Section Controler (2) Video (2) ABB (1) FAQ (1) GDCE Exam (1) IRMS (Indian Railway Management Service (1) JUNIOR ENGINEER (Non -AC) GRADE - II (1) Minimum Wages Act (1) Project & Planning (1) Q BANK & Answer - C & W ( Carriage & Wagon ) (1) Q Bank - Instructor (1) Q Bank - AMM (1) Q Bank - All Department (1) Q Bank - Ballast Train Checker (1) Q Bank - CCTC (1) Q Bank - Complaints Inspector (1) Q Bank - GK (Computer) (1) Q Bank - Leave Rule (1) Q Bank - Mason (1) Q Bank - Maths (1) Q Bank - NPS (New Pension Scheme) (1) Q Bank - OS / Clerk Typist (1) Q Bank - Pass Rule (1) Q Bank - Planning Inspector (1) Q Bank - Railway (GK) (1) Q Bank - Stenographer (1) Q Bank - Track Machine (1) Q Bank - Traffic Costing Inspector (1) Question Bank - Technicians of TLAC Group. (1) Short Notes - Establishment (1) Short Notes - Operating / Traffic (1)