SEARCH

Q Bank & Answer - Electrical Engineer - ALTERNATOR AND RRU

1. Alternator is a device that converts [ a ]

a. Mechanical energy into electrical energy

b. Electrical energy into mechanical energy

c. Chemical energy into electrical energy

d. None of the above

Answer - a. Mechanical energy into electrical energy


2. Both field winding and 3 phase winding of AC coach alternator 120V are provided on _____ [ a]

a. Stator

b. Rotor

c. Both a and b

d. None

Answer -a. Stator


3. TL/AC coach alternator 120V designed to have ______________ [a ]

a. Residual magnetism

b. Permanent magnetism

c. Both a and b

d. None of the above

Answer -a. Residual magnetism


4. Recommended Cut in speed of 4.5 KW TL alternator is by RDSO with MA RR unit _____ [ a ]

a. 357 rpm

b. 600 rpm

c. 1100 rpm

d. 2500 rpm

Answer - a. 357 rpm


5. Minimum speed for full output of 4.5 KW 120V TL alternator, recommended by RDSO is ___ [ b ]

a. 357 rpm

b. 600 rpm

c. 1500 rpm

d. 2500 rpm

Answer - b. 600 rpm


6. Maximum speed of TL/AC coach alternator is [ d ]

a. 400 rpm

b. 800 rpm

c. 1500 rpm

d. 2500 rpm

Answer -d. 2500 rpm


7. Field coils of 120V TL/AC coach alternator are connected in [ a ]

a. Series

b. Parallel

c. Star

d. Delta

Answer - a. Series


8. Three phase windings of 120V TL/AC coach alternator are connected in [a ]

a. Star

b. Delta

c. Series

d. Parallel

Answer - a. Star


9. Size of V belts used for driving 110V 4.5KW TL alternators [ a]

a. C122

b. C118

c. C124

d. None

Answer - a. C122


10. Size of V belt used for driving 110V, 18, 22.5KW AC coach Alternators [ a ]

a. C122

b. C118

c. C124

d. None

Answer - a. C122


11. Number of V belts used for driving 110V 4.5KW TL alternator is ___________ [ a ]

a. 4

b. 6

c. 12

d. None

Answer - a. 4

12. Number of V belts used for driving 110V 18KW & 25KW AC alternator is _______ [ c ]

a. 4

b. 6

c. 12

d. None

Answer - c. 12


13. DC output voltage of Alternator /Regulator of 110V TL/AC coach is [ a ]

a. (110-140) DC

b. (70-90) DC

c. (90-120) DC

d. None

Answer -  a. (110-140) DC


14. Rated DC output current of 4.5KW 110V Alternator is ____________ [ a ]

a. 37.5A

b. 19A

c. 43A

d. None

Answer -   a. 37.5A


15. Rated DC output current of 18KW 110V Alternator is ____________ [ c ]

a. 193A

b. 175A

c. 135A

d. None

Answer -   c. 135A

16. Rated DC output current of 25KW 110V Alternator is ____________ [ a ]

a. 193A

b. 175A

c. 135A

d. None

Answer -    a. 193A


17. Pitch circle diameter of Axle pulley of 110V TL system [ c ]

a. 200mm

b. 140mm

c. 572.6mm

d. None

Answer -  c. 572.6mm

18. Pitch circle diameter of Axle pulley of 110V AC coach system [ c ]

a. 200mm

b. 584mm

c. 572.6mm

d. None

Answer -  c. 572.6mm


19. As per the latest SMI, the voltage setting of alternator 4.5KW 110V for passenger train with flooded batteries is ____________ [ c ]

a. 127V DC

b. 124V DC

c. 128.5V DC

d. None

Answer -   c. 128.5V DC


20. As per the latest SMI, the voltage setting of ac alternator 18KW 110V with flooded batteries is [ c ]

a. 129V DC

b. 124V DC

c. 128V DC

d. None

Answer -    c. 128V DC


21. As per the latest SMI, the voltage setting of alternator 4.5KW 110V for passenger train with VRLA
batteries is ____________ [ b ]

a. 123+/-0.5V DC

b. 128.5+/-0.5V DC

c. 121+/-0.5V DC

d. None

Answer -    b. 128.5+/-0.5V DC

22. As per the latest SMI _____the voltage setting of alternator 4.5KW 110V for mail/express trains with VRLA batteries is ____________ [ b ]

a. 123+/-0.5V DC

b. 128.5+/-0.5V DC

c. 121+/-0.5V DC

d. None

Answer -    b. 128.5+/-0.5V DC

23. As per the latest SMI the voltage setting of alternator 4.5KW 110V for super fast trains with VRLA batteries is ____________ [ b ]

a. 123+/-0.5V DC

b. 128.5+/-0.5V DC

c. 121+/-0.5V DC

d. None

Answer - b. 128.5+/-0.5V DC

24. As per the latest SMI the voltage setting of AC coach alternator 110V for passenger train with VRLA batteries is ____________ [ a ]

a. 128+/-0.5V DC

b. 127+/-0.5V DC

c. 126+/-0.5V DC

d. None

Answer - a. 128+/-0.5V DC


25. As per the latest SMI the voltage setting of AC coach alternator 110V for Mail/express train with VRLA batteries is ____________ [ a ]

a. 128+/-0.5V DC

b. 127+/-0.5V DC

c. 126+/-0.5V DC

d. None

Answer -  a. 128+/-0.5V DC

26. As per the latest SMI the voltage setting of AC coach alternator 110V for super fast train with VRLA batteries is ____________ [ a ]

a. 128+/-0.5V DC

b. 127+/-0.5V DC

c. 126+/-0.5V DC

d. None

Answer - a. 128+/-0.5V DC


27. The purpose of TL Alternator used in Railways. [ d ]

a. Charging the caoch battery on train run

b. Working of lights and fans in the coach during train run

c. Sharing the load to other coaches in case of emergency

d. All the three above

Answer - d. All the three above


28. The capacity of alternator used for BG coach 110V Train Lighting system. [ b ]

a. 3KW

b. 4.5KW

c. 12KW

d. None

Answer  - b. 4.5KW


29. The capacity of alternator used for BG coach 110V roof mounted AC coach [ c ]

a. 12KW

b. 18KW

c. 25KW

d. None

Answer  -  c. 25KW


30. The capacity of alternator used for BG coach 110V under slung AC caoch. [ c ]

a. 25KW

b. 12KW

c. 18KW

d. None

Answer  - c. 18KW


31. The PCD (pitch circle diameter) of 25KW 110V alternator pulleys is [ b ]

a. 584mm +/- 0.4mm

b. 200+/-0.3 mm 

d. None

c. 100 mm

Answer  - b. 200+/-0.3 mm 


32. The field resistance of 4.5KW 110V TL alternator has [ a ]

a. 4.5 +/-0.5 ohms

b. 6.0+/-0.5 ohms

c. 10+/-0.5 ohms

d. None

Answer  -  a. 4.5 +/-0.5 ohms

33. The resistance between two phases of 4.5KW 110V TL alternator is [ a ]

a. 0.4 +/-0.05 ohms

b. 0.8 +/-0.10 ohms

c. 4.5 +/-0.5 ohms

d. None

Answer  - a. 0.4 +/-0.05 ohms


34. The purpose of providing anti rotating clamp near suspension arrangement of alternator is [ d ]

a. Not to rotate suspension pin of alternator

b. Not to damage the nylon bushes of alternator/ suspension bracket

c. Not to damage the suspension bracket/boss of alternator

d. All of the above

Answer  -  d. All of the above


35. The insulation material recommended for alternator windings of 4.5 KW 110V shall be [ c ] __________ class.

a. A

b. B

c. F

d. None

Answer  -  c. F


36. The voltage setting of Alt/RR unit is to be set in far with current and RPM for 4.5KW is [ a ]

a. Half rated capacity of the alt as load as 1500 RPM

b. ¼ rated capacity of the alt as load at 1000 RPM

c. Full rated capacity of alt as load at 2550 RPM

Answer  -  a. Half rated capacity of the alt as load as 1500 RPM


37. While measuring insulation resistance of 110V alternator/rectifier cum regulator the rating of megger is to be used is [ b ]

a. 100V DC megger

b. 500V DC megger

c. Both a nad b

d. None

Answer  -  b. 500V DC megger
 

38. The resistance between two phase of 25KW KEL alternator is about [ a ]

a. 0.0530746 ohms

b. 0.034 to 0.038

c. 44.2 mille ohms

d. None

Answer  -  a. 0.0530746 ohms


39. The field resistance of 25KW KEL alternator about [ a ]

a. 9.7568 ohms

b. 8+/-0.5 ohms

c. 10.72 ohms

d. None

Answer  - a. 9.7568 ohms


40. The gap between two halves of axle pulley to be maintained is [ a ]

a. 3.0 +/-0.5 mm

b. 6mm +/- 0.5 mm

c. 4mm +/- 0.5 mm

d. None

Answer  -  a. 3.0 +/-0.5 mm


41. Codal life of 4.5, 18, 22.75 & 25 KW alternator / RR unit [ a ]

a. 12 years

b. 25 years

c. 15 years

d. None

Answer  - a. 12 years


42. Codal life of 120 AH VRLA Battery [ b ]

a. 5 years

b. 4 years

c. 3 years

d. None

Answer  -  b. 4 years


43. Codal life of 120 AH Flooded Battery [ b ]

a. 5 years

b. 4 years

c. 3 years

d. None

Answer  -  b. 4 years


44. Codal life of Battery charger [ b ]

a. 12 years 
b. 15 years
c. 25 years 
d. None

Answer  - b. 15 years

45. Codal life of Coach wiring [ b ]

a. 12 years

b. 15 years

c. 20 years

d. None

Answer  - b. 15 years


46. Codal life of Carriage fans [ a ]

a. 10 years

b. 12 years

c. 15 years

d. None

Answer  - a. 10 years


47. The distance to be maintained while fixing axle pulley on wheel, from wheel hub to axle pulley outer wedge for 25 KW alternator is [ a ]

a. 225 mm

b. 240 mm

c. 145 mm

d. None

Answer  - a. 225 mm


48. The distance to be maintained while fixing axle pulley on wheel, from wheel hub to axle pulley outer wedge for 18 KW alternator is [ b ]

a. 225 mm

b. 240 mm

c. 145 mm

d. None

Answer  - b. 240 mm


49. The distance to be maintained while fixing axle pulley on wheel, from wheel hub to axle pulley outer wedge for 4.5 KW alternator is [ c ]

a. 225 mm

b. 240 mm

c. 145 mm

d. None

Answer  -  c. 145 mm


50. ‘V’ belt dropping/smoking/burning due to mechanical failure [ c ]

a. Brake block jamming

b. Guide cups of damper’s have dropped

c. Both a and b

d. None

Answer  -   c. Both a and b


51. ‘V’ belt dropping/smoking/burning due to electrical failure [ d ]

a. Load on Alt is heavy

b. Wrong alignment

c. Loose/excessive tension

d. All of the above

Answer  -  d. All of the above


52. The minimum insulation resistance to be maintained for 4.5KW alternator is [ b ]

a. 1 Mega ohm

b. 2 Mega ohm

c. 20 Mega ohm

d. None

Answer  -  b. 2 Mega ohm


53. The minimum insulation resistance to be maintained for 18 & 25 KW alternators [ b ]

a. 20 mega ohm

b. 2 Mega ohm

c. 5 Mega ohm

d. None

Answer  - b. 2 Mega ohm


54. No. of ET’s used in 25 KW RR Unit MA type [ c ]

a. 2

b. 1

c. Zero

d. None

Answer  -  c. Zero
 

55. No. of MA’s used in 25 KW MA type RR Unit [ a ]

a. 2

b. 1

c. Zero

d. None

Answer  - a. 2

56. Width of grooved axle pulley of 4.5KW alternator is [ ]

a. 200mm

b. 190mm

c. 136mm

d. None

Answer  -  

57. Width of grooved axle pulley of 18 and 25 KW alternator is [ ]

a. 200 mm

b. 190 mm

c. 136 mm

d. None

Answer  -  


58. The type of suspension bushes are to be provided TL/AC alternators/ suspension bracket as per RDSO specification no RDSO / PE/Ac/0006/99 (Rev.0) [ b ]

a. Cast nylon bushes

b. Nylon 66 bushes

c. MS bushes

d. All of the above

Answer  -  b. Nylon 66 bushes

 
59. Residual magnetism lost in the alternator core the reason is [ c ]

a. Field polarity changed

b. Alternator is in idle condition for long time

c. Both a and b

d. None of the above

Answer  -   c. Both a and b


60. As per the Railway Board letter No. 2006/Elec(G)/138/3Pt. I unit Exchange spare recommended for alternators and Regulators for TL/AC depot [a ]

a. 5%

b. 10%

c. 15%

d. None

Answer  - a. 5%


61. ERRU stands for [ a ]

a. Electronic Rectifier cum Regulator Unit

b. Electromagnetic Rectifier cum Regulator unit

c. Electrostatic Rectifier cum Regulator Unit

d. None

Answer  - a. Electronic Rectifier cum Regulator Unit


62. IGBT stands for [ a ]

a. Insulated Gate Bipolar Transistor

b. Injection Gate Bipolar Transistor

c. Indicator gate Bipolar Transistor

d. None

Answer  - a. Insulated Gate Bipolar Transistor


63. IGBT is [ a ]

a. Fast switching device

b. Slow switching device

c. Very fast switching device

d. None

Answer  - a. Fast switching device


64. The size of capacity of fuses to be provided for 25kW ERRU in phase circuit [ b ]

a. 160A

b. 200A

c. 220A

d. None

Answer  - b. 200A


65. UVC used in ERRU must be [ a ]

a) Suitable to work with all capacities

b) Suitable to work with all makes

c) Both a and b

d) None

Answer  - a) Suitable to work with all capacities


66. The battery charging current limit with 4.5kW ERRU is to be set at [ a ]

a. 24A +/-2A

b. 12A +/- 2A

c. 36A +/- 2A

d. None

Answer  -  a. 24A +/-2A


67. TL alternator 4.5 KW 130 V is_______ [ a ]

a) 4 V belts drive machine

b) 6 V belts drive machine

c) 12 V belts drive machine

d) None of the above

Answer  - a) 4 V belts drive machine


68. Non drive end bearing of 4.5 kw 120v 4.5kw TL alternator is__ [ a ]

a) SKF 6309 

b) SKF NU311 

c) SKF 6200 

d)None

Answer  - a) SKF 6309 


69. Driving end bearing of 4.5 kw 120 V 4.5 kw TL alternator is_____ [ b ]

a) SKF 6309 

b) SKF NU311 

c) SKF 6200

 d)None

Answer  -  b) SKF NU311 


70. Recommended Cut in speed of 4.5 kw TL alternator is by RDSO with [ a ] MA RR unit

a) 357 rpm 

b) 600 rpm 

c) 1100 rpm 

d)2500rpm

Answer  - a) 357 rpm 


71. Minimum speed for full output of 4.5 kw 120V TL alternator, [ b ] Recommended by RDSO is

a) 357 rpm 

b) 600 rpm 

c) 1100 rpm 

d)2500rpm

Answer  - b) 600 rpm 
 

72. Field coils of 120VTL/AC coach alternator are connected in [ a ]

a) Series 

b) Parallel 

c) Star 

d)Delta

Answer  - a) Series 


73. Three phase windings of 120V TL/AC coach alternator are connected in [ a ]

a) Star 

b) Delta 

c) Series 

d)Parallel

Answer  - a) Star 


74. Field coils of TL coach alternators are located on [ a ]

a) Stator 

b) Rotor 

c) Both a and b 

d) None

Answer  -  a) Stator 


75. Each field coil of TL/AC coach alternator embraces _______ total number of there phase winding slots. [ a ]

a) Half of the

b) One fourth of the

c) Three fourth of the

d) None

Answer  - a) Half of the


76. Size of V belts used for driving 110V 4.5 kw TL alternators [ a ]

a) C122 

b) C118 

c) C124 

d) None

Answer  - a) C122 


77. Number of V belts used for driving 110 V 4.5 kw TL alternator is [ a ]

a) 4 

b) 6 

c) 12 

d) None

Answer  - a) 4 


78. Numbers of alternator pulleys are available on 4.5 kw TL Alternator. [ a ]

a) 1 

b) 2 

c) 3 

d) None

Answer  - a) 1 


79. Numbers of Alternators pulleys are available on BG AC coach Alternator. [ b ]

a) 1 

b) 2 

c) 3 

d) None

Answer  -  b) 2 


80. Residual magnetism retains in ____________ [ b ]

a) Rotor core 

b) Stator Core 

c) Rotor teeth 

d) None

Answer  -  b) Stator Core 


81. Number of slots are available in stator for 3Phase ac winding  in 4.5 KW 120V Alternator

a) 36 

b) 60 

c) 18 

d) None

Answer  - a) 36 


82. 3 Phase AC voltages are first produced in ac winding in Alternator by [ a ]

a) Residual magnetism 

b) Permanent magnetism

C) Both a and b 

d) None

Answer  - a) Residual magnetism 


83. When the rotor of 4.5 kw 120V alternator is rotated by hand the voltage developed in the 3 phase winding will be


a) 3.5 v 

b) 12v 

c) 24v 

d) None

Answer  - a) 3.5 v 


84. DC output voltage of Alternator/Regulator of 110 V TL/AC coach is [ a ]

a) (110-140) DC 

b) (70-90) DC 

c) (90-120) DC 

d)None

Answer  - a) (110-140) DC 


85. Rated DC output current of 4.5kw 110v Alternator is [ a ]

a) 37.5A 

b) 19A 

c) 43A 

d)None

Answer  - a) 37.5A 


86. Rated DC output current of 3kw 110v Alternator is [ b ]

a) 37.5A 

b) 19A 

c) 43A 

d)None

Answer  - b) 19A 


87. Rated DC output current of 25kw 110v Alternator is [ a ]

a) 193A 

b) 175A 

c) 135A 

d)None

Answer  - a) 193A 


88. Pitch circle diameter of Axle pulley of 110v TL system [ c ]

a) 200mm 

b) 140mm 

c) 572.6mm 

d)None

Answer  - c) 572.6mm 


89. Pitch circle diameter of Axle pulley of 110v AC coach system [ c ]

b) 200mm 

b) 140mm 

c) 572.6mm 

d)None

Answer  - c) 572.6mm 


90. As per the latest SMI, the voltage setting of alternator 4.5kw 110v for  Express/ mail trains with flooded batteries is _________

a) 128.5v DC 

b) 124v DC 

c) 122v DC 

d)120v DC

Answer  - a) 128.5v DC 


91. As per the latest SMI, the voltage setting of AC coach alternator 110v  for passenger train with VRLA batteries is

a) 128+/-0.5vDC 

b) 127 +/- 0.5vDC 

c) 126 +/-0.5vDC 

d)None

Answer  - a) 128+/-0.5vDC 


92. The purpose of TL Alternator used in Railways [ d ]

a) Charging the coach battery on train run

b) Working of lights and fans in the coach during train run

c) Sharing the load to other coaches in case of emergency

d) All the above

Answer  - d) All the above


93. The purpose of Ac coach Alternator used in Railways [ d ]

a) Charging the coach battery on train run

b) Working of lights and fans in the coach during train run

c) Sharing the load to other coaches in case of emergency

d) All the above

Answer  - d) All the above


94. The capacity of alternators are used for BG coach 110v Train Lighting system. [ b ]

a) 3kw 

b)4.5kw 

c)12kw 

d)None

Answer  - b)4.5kw 


95. The capacity of alternators are used for BG 110v roof mounted AC coach [ c ]

a) 3kw 

b) 18kw 

c)25kw 

d)None

Answer  - c)25kw 


96. Number of Alternators are provided for AC sleeper, AC chair car,  AC composite coach

a) 1 

b)2 

c)3 

d)None

Answer  - a) 1 


97. The AC winding/ Main winding of TL/AC coach alternator has _______ phase winding

a) Single 

b) Double 

c) Three 

d) None

Answer  - a) Single 


98. The safety items of TL/AC alternator are [ a ]

a) Suspension hanger pin with bushes and Cottar Pin

b) Alternator Suspension arrangement

c) Alt pully & nut

d) All the above

Answer  - a) Suspension hanger pin with bushes and Cottar Pin


99. NU 311 bearing is [ a ]

a) Roller bearing

b) Ball bearing

c) Both a and b

d) None

Answer  - a) Roller bearing


100. The field resistance of 4.5kw 110v TL alternators has [ a ]

a) 4.5+/-0.5 ohms

b) 6.0+/-0.5 ohms

c) 10+/-0.5 ohms

d) None

Answer  - a) 4.5+/-0.5 ohms


101. MA type RR units are working on the principle [ a ]

a) Saturation and de saturation of magnetic core

b) Mutual induction

c) BJT

d) None

Answer  - a) Saturation and de saturation of magnetic core


102. Generally the voltage setting of the alternator is to be set at_______  At 1500rpm

a) Full rated current

b) Half rated current

c) 2/3rd rated current

d) None

Answer  -  b) Half rated current


103. Both directions of train run, the polarity of Dc output supply of TL/AC alternator [ b ]

a) Changes 

b)Do not change

 c)Change at start 

d) None

Answer  -  b)Do not change


104. The mating of pulley with shaft of TL/AC alternator shall be [ a]

a) 80% 

b) 70% 

c) 60% 

d)50%

Answer  - a) 80% 


105. The cleat of alternator is to be made of [ a]

a) Fibre glass in forced fire retardant DNC

b) Bakelite

c) Phenolicd

d) None

Answer  - a) Fibre glass in forced fire retardant DNC


106. Rotor shaft of KEL 110v 4.5kw alternator made up of [ a]

a) EN 24 

b) EN 8 

c)Both a and b 

d)None

Answer  - a) EN 24 


107. Type of suspension bushes to be used while mounting alternators [ b ] as per latest RDSO instructions are

a) Cast Nylon 

b)Nylon 66 

c)MS 

d)None

Answer  - b)Nylon 66 
 

108. The insulation resistance of alternator when measured with megger  the IR value should not be less than

a) 2 mega ohms 

b)5 mega ohms 

c)both a and b 

d)None

Answer  - b)5 mega ohms 


109. In case of over voltage in 4.5kw 120v RR unit, the tripping voltage  of relay may be set at

a) 145+/-2

b) 150+/-2

c) 135+/-2

d)None

Answer  - a) 145+/-2


110. The number of safety chains provided for 18kw and 25kw alternator [ b ]

a) 2 

b) 3 

c) 4 

d)None

Answer  - b) 3 


111. The cut in speed of 25kw alternator is not more than [ a ]

a) 400rpm 

b) 600rpm

c) 800rpm

d)None

Answer  -   a) 400rpm 


112. The MFO of 25 kw alternator is not more than [ c ]

a) 400rpm

b) 600rpm

c) 800rpm

d)None

Answer  - c) 800rpm
 

113. The field resistance of 25 kw KEL alternator about [ a ]

a) 9.7568 ohms 

b) 8 +/-0.5 ohms 

c) 10.72 ohms 

d)None

Answer  -  a) 9.7568 ohms 
 

114. To prevent breakage of shaft during service the following test should be  Done as per RDSO SMI

a) Non destruction dye-penetrate test

b) Shock pulse meter test

c) Ultrasonic test

d) None

Answer  -  a) Non destruction dye-penetrate test


115. The gap between two halves of axle pulley to be maintained is [ a ]

a) 3.0mm+/- 0.5mm 

b)6mm +/- 0.5mm 

c)4mm +/-0.5mm 

d) None

Answer  -  a) 3.0mm+/- 0.5mm 


116. Before lifting coach body, the following electrical items as to be removed,  otherwise coach body will not separate from trolley

a) Belt tensioning mechanism

b) V Belts

c) Alternator cables

d) All the above

Answer   - a) Belt tensioning mechanism


117. Rating of AC fuses to be provided in 25kw MA type RR unit [ b ]

a) 125A HRC 

b) 160A HRC 

c)Either a or b 

d)None

Answer   - b) 160A HRC 


118. The rating of filed fuse to be provided in 4.5kw 110v HMTD MA type RRU [ a ]

a) 6A 

b)2A 

c)4A 

d)None

Answer   - a) 6A 


119. Field resistance of 25 kw alternator [ a ]

a) 9.75 ohms 

b)4.5 ohms 

c)10 ohms

d) none

Answer   -  a) 9.75 ohms 


125. Codal life of 120 AH VRLA battery [ b ]

a) 5 yrs 

b)4 yrs 

c)3 yrs 

d) None

Answer   - b)4 yrs 


126. Codal life of 120 AH Flooded battery [ b ]

a) 5 yrs 

b)4 yrs 

c)3 yrs 

d) None

Answer   -  b)4 yrs 


127. Codal life of Battery charger [ b ]

a) 12 yrs 

b)15 yrs 

c)25 yrs

d) None

Answer   - b)15 yrs 


128. Codal life of coach wiring [ b ]

a) 12 yrs 

b)15 yrs 

c)20 yrs

d) None

Answer   -  b)15 yrs 

No comments: