SEARCH

Q Bank & Answer Electrical Engineer - ELECTRICAL UNITS: EQUIVALENTS & FORMULAE

1. One HP = [ b ]

(a) 756 watts 

(b) 746 watts 

(c) 860 watts 

(d) 856 wats

Answer - (b) 746 watts 


2. Torque in ft. lbs. = [ a ]

(a) HP x 33000 / (RPM x 2) 

(b) HP x 2 / (RPM x 33000)

(b) HP x RPM / (2 x 33000) 

(d) RPM x 2 / (HP x 33000)

Answer -  (a) HP x 33000 / (RPM x 2) 


3. Current = [ a ]

(a) Watts/Volts 

(b) Volts/Watts

(c) Kilowatt/Volts 

(d) Kilovolt/watt

Answer - (a) Watts/Volts 


4. Motor output in HP= [ a ]

(a) KW input x efficiency/0.746 

(b) KW input x 0.746/efficiency

(c) Efficiency x 0.746/KW input 

(d) 0.746/(KW input x efficiency)

Answer - (a) KW input x efficiency/0.746 


5. kVA equal to [ d ]

(a) 1000 x Amps/ volts 

(b) volts x Amps x 1000

(c) Volts x 1000/Amps 

(d) Amps x volts/1000

Answer - (d) Amps x volts/1000


6. Power factor = [ a ]

(a) True Power/Apparent power 

(b) Apparent power/True power

(c) Average power/True power 

(d) Apparent power/Average power

Answer - (a) True Power/Apparent power 


7. True power in three-phase circuit in Kilowatt is [ b ]

(a) 1.414 x volts x amperes x pf/1000 

(b) 1.73 x volts x amperes x pf/1000

(c) Volts x Amperes x pf/1000 

(d) Volts x Amperes x 1000/pf

Answer -  (b) 1.73 x volts x amperes x pf/1000


8. Amperes drawn by single-phase motor are equal to [ c ]

(a) Efficiency x Volts x pf / (HP x 746) 

(b) Efficiency x pf/(volt x HP x 746)

(c) HP x 746 / (Efficiency x volts x pf) 

(d) HP x746 x volts/(Efficiency x pf)

Answer -  (c) HP x 746 / (Efficiency x volts x pf) 


9. Amperes drawn by three phase motor are equal to [ c ]

(a) Efficiency x Volts x pf / (HP x 746) 

(b) Efficiency x pf/(volt x HP x 746)

(c) HP x 746/(Efficiency x volts x pf x 1.73) 

(d) HP x 746 x volts/(Efficiency x pf)

Answer - (c) HP x 746/(Efficiency x volts x pf x 1.73) 


10. One Kilowatt = [ a ]

(a) 1.314 HP 

(b) 13.41 HP 

(c) 134.1 HP 

(d) 1341 HP 

Answer - (a) 1.314 HP 


11. One Kilowatt = [ d ]

(a) 1360 Metric HP 

(b) 136 Metric HP

(c) 13.60 Metric HP 

(d) 1.360 Metric HP

Answer - (d) 1.360 Metric HP


12. One Kwh = [ c ]

(a) 34.13 BTU 

(b) 44.13 BTU

(c) 3.413 BTU 

(d) 4.413 BTU

Answer -  (c) 3.413 BTU 


13. One Kwh = [ b ]

(a) 1000 calories 

(b) 860 calories

(c) 740 calories 

(d) 970 calories

Answer - (b) 860 calories


14. One BTU = [ a ]

(a) 0.2520 calories 

(b) 2.520 calories 

(c) 25.20 calories 

(d) 252.0 calories

Answer -  (a) 0.2520 calories 


15. One Calorie = [ d ]

(a) 39.68 BTU 

(b) 4.968 BTU 

(c) 49.68 BTU 

(d) 3.968 BTU

Answer - (d) 3.968 BTU


16. One foot pound = [ a ]

(a) 0.1383 M Kg 

(b) 1.383 M Kg 

(c) 13.83 M Kg 

(d) 138.3 M Kg

Answer - (a) 0.1383 M Kg 


17. One BTU = [ d ]

(a) 0.1076 M Kg 

(b) 1.076 M Kg 

(c) 10.76 M Kg 

(d) 107.6 M Kg

Answer -  (d) 107.6 M Kg


18. One Kilowatt = [ b ]

(a) 202 M Kg/sec 

(b) 102 M Kg /sec 

(c) 20.2 M Kg/sec 

(d) 10.2 M Kg/sec

Answer -  (b) 102 M Kg /sec 


19. One Electrical Unit = [ a ]

(a) 1 Kwh 

(b) 1 Kw 

(c) 1 kVA 

(d) Watt

Answer -  (a) 1 Kwh 


20. Power factor = [ a ]

(a) R/Z 

(b) Z/R 

(c) V/I 

(d) I/V

Answer -   (a) R/Z 


21. The current rating of PVC insulated and PVC sheathed four core , armoured aluminium cable of size 120 sq mm (laid direct in ground) is approximately [ b ]

(a) 80 amps 

(b) 185 amps 

(c) 290 amps 

(d) 320 amps

Answer -   (b) 185 amps 


22. The current rating of PVC insulated and PVC sheathed four core , armoured aluminium cable of size 70 sq mm (laid in duct) is approximately [ a ]

(a) 115 amps 

(b) 210 amps 

(c) 290 amps 

(d) 350 amps 

Answer - (a) 115 amps 


23. The current rating of PVC insulated and PVC sheathed four core , armoured aluminium cable of size 50 sq mm (laid in air) is approximately [ b ]

(a) 65 amps 

(b) 105 amps 

(c) 200 amps 

(d) 250 amps

Answer - (b) 105 amps 


24 The current rating of PVC insulated and PVC sheathed four core , armored aluminium cable of size 35 sq mm (laid direct in ground) is approximately [ a ]

(a) 92 amps 

(b) 160 amps 

(c) 200 amps 

(d) 250 amps

Answer - (a) 92 amps 


25 The current rating of PVC insulated and PVC sheathed four core , armoured aluminium cable of size 25 sq mm (laid direct in ground) is approximately [ b ]

(a) 55 amps 

(b) 76 amps 

(c) 90 amps 

(d) 150 amp 

Answer - (b) 76 amps 

No comments:

Disclaimer: The Information/News/Video provided in this Platform has been collected from different sources. We Believe that “Knowledge Is Power” and our aim is to create general awareness among people and make them powerful through easily accessible Information.