01. Capacity of rotary switches provided in rotary junction box is [ a ]
a)40A
b)16A
c)10A
d)15A
Answer - a)40A
02. Capacity of limit switch provided for alarm chain pulling indication light circuit [ a ]
a) 10A
b)15A
c)35A
d)40A
Answer - a) 10A
03. Size of rewirable fuse recommended for individual fan in 110V TL system is [ a ]
a)35 SWG R/W
b) 29 SWG R/W
c)20 SWG R/W
d) 22 SWG R/W
Answer - a)35 SWG R/W
04. Positive and negative cable in roof runs through on either side of coach to avoid [ c ]
a) earth leakage
b) over load
c) short circuits
d) none
Answer - c) short circuits
a) Lavatory lights, door way lights and Night lights and 50% of compartment lights
b) Lavatory lights
c) Lavatory and door lights
d) Lavatory, door lights and Night lights
Answer - a) Lavatory lights, door way lights and Night lights and 50% of compartment lights
a) 32W
b)10W
c)80W
d)60W
Answer - a) 32W
a) 40A HRC
b) 16A HRC
c) 10 A HRC
d)4 A HRC
Answer - a) 40A HRC
a) Corrosion of the battery box from splitting of acid
b) Electrical insulation for battery and battery box
c) Vibration of batteries
d) all of the above
Answer - d) all of the above
a)50mm
b)150mm
c)100mm
d)none
Answer - b)150mm
a)400mm sweep
b)300 mm sweep
c)225 mm sweep
d)200 mm sweep
Answer - a)400mm sweep
11. The total number of V belts provided to the drive TL alternator 4.5KW are [ a ]
a) 4
b)6
c)2
d)3
Answer - a) 4
12. The train lighting wiring is [ b ]
a) two wire earthed system
b) two wire unearthed system
c) one wire earthed system
d)none of the above
Answer - b) two wire unearthed system
a) 2mega ohms
b) 1 mega ohms
c)3 mega ohms
d)0.5 mega ohms
Answer - a) 2mega ohms
a) 2mega ohms
b) 1 mega ohms
c)3 mega ohms
d)none
Answer - b) 1 mega ohms
a) loose connections
b)short circuits and earth faults
c) undersize cables
d) all of the above
Answer - d) all of the above
16. The earth leakage can be checked both positive and negative cables at a time by [a ]
a) double test lamp method
b) 500V megger
c) single test lamp
d)none of the above
Answer - a) double test lamp method
17. Double test lamps are connected in [ a ]
a)series
b) parallel
c) both a&
b d)none
Answer - a) series
a) healthy
b)having positive earth
c)having negative earth
d) none
Answer - c) having negative earth
19. When double test lamp is connected to EFTB, red lead lamp does not glows and blue lead lamp glows then coach is [ b ]
a) healthy
b)having positive earth
c)having negative earth
d) both B&C
Answer - b)having positive earth
20. The insulation resistance of coach is to be measured with [ a ]
a ) megger
b)ohm meter
c)continuity meter
d)none
Answer - a ) megger
a) tong tester
b) tacho meter
c) photo meter
d)none
Answer - a) tong tester
a)parallel
b)series
c)series and parallel
d)none
Answer - a)parallel
a)parallel
b)series
c)series and parallel
d)none
Answer - b)series
a) same wattage
b) different wattage
c)any wattage
d)none
Answer - a) same wattage
a)same polarity
b)opposite polarity
c)any polarity
d)none
Answer - a)same polarity
a) alternator Field/AC wire defective
b) no residual magnetism
c) rectifier /regulator box defective
d)any of the above
Answer - d)any of the above
27. Cables used for wiring in coaches should have [ a ]
a) minimum joints
b)five joints
c)maximum joints
d)none
Answer - a) minimum joints
28. The level of illumination will be measured by [ c ]
a)photo meter
b)lux meter
c)both A&B
d)none
Answer - c)both A&B
29. The percentage of spare coaches should be available in TL maintenance depot on traffic account is[ b ]
a) 10
b) 5
c) 6
d) none
Answer - b) 5
30. The percentage of spare coaches should be available in AC maintenance depot on traffic account is [ c ]
a) 12
b) 5
c) 6
d)none
Answer - c) 6